Technology
|
Control |
Indigenous micro-controller based of art equivalent technology |
Memory |
Reliable flash / E2prom for program / data retention |
Inputs/Outputs |
Protected using OPTO isolation |
Power Supply |
Efficient SMPS to withstand voltage variations |
———————————————————————————————————– |
Economy
|
Economical solutions to cater entire range – Conventional to full featured Machines |
———————————————————————————————————– |
Reliability
|
Proven through years of reliable operations |
———————————————————————————————————– |
Display
|
16 X 2 LCD Display |
———————————————————————————————————– |
Size
|
Most compact hence effective space utilization |
———————————————————————————————————– |
Quality
|
Accurate timings, Fast response provides consistent performance & hence improved quality |
———————————————————————————————————– |
Productivity
|
Reduces electrical maintenance / down time of the machine hence ensures better productivity |
———————————————————————————————————– |
Installation
|
Easy one to one wiring for all inputs / outputs hence both time & cost-effective installation |
All external connections through detachable connectors |
Channel Din rail card mounting |
———————————————————————————————————– |
Inputs
|
Expandable Digital Inputs & Analogue Inputs |
———————————————————————————————————– |
Outputs
|
Expandable Digital Outputs & Analogue Outputs |
———————————————————————————————————– |
Timers
|
0 – 999.9 / 0 – 99.99 Seconds |
———————————————————————————————————– |
Operation
|
Mode: Auto / Manual |
Auto operation of liquor heating/cooling for main vessel |
Pressurizing / Depressurizing of main vessel |
Fill/drain/rinse off main vessel as well as colour tank |
Transfer of color chemical from main vessel to color tank or vice versa |
Messaging of functions on all screens. |
Operator call facility for loading/unloading, sampling, chemical addition, dyes addition, end of program, fabric entanglement. |
Linear transducers for level indication |
35 Permanent programmed each of 100 steps |
———————————————————————————————————– |
Testing & Troubleshooting
|
Extensive input / output / temperature test facility |
Indications at various level for diagnostics |
———————————————————————————————————– |
After sales services
|
Seldom required |
Immediate replacement in worst case of failure, subject to warranty terms & conditions |
———————————————————————————————————– |
Optional Features
|
Linear transducers for level indication |
Data logging & analysis * Hourly production for last 24 hours |
RS 232 / RS 485 Serial interface |
Analog output for dosing |
Safety
|
Password Protection for engineering parameter |
———————————————————————————————————– |
Specifications
|
———————————————————————————————————– |
Input
|
Power |
24 Vac / Vdc ± 10% |
Consumption 10 VA max. |
———————————————————————————————————– |
Control
|
Digital |
10-30 Vdc, 30 mA , NPN /NO |
Response Time |
10 ms |
———————————————————————————————————– |
Output
|
Digital |
Open collector |
24 Vdc / 30 mA |
———————————————————————————————————– |
Environment
|
Temperature |
0-50 ºC, Single zone: Three wire RTD profile controller. |
Humidity |
5-95% Rh, Noncondensing |
———————————————————————————————————– |
Dimension
|
Standard |